r9725[0...2]
SI Motion diagnostics STOP F / SI Mtn Diag STOP F
VECTOR_G
Can be changed: -
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
For index 0:
Displays the message value that resulted in the STOP F on the drive.
Value = 0:
The Control Unit signaled a STOP F.
Value = 1 ... 999:
Number of the incorrect date in the crosswise data comparison between the monitoring channels.
Value >= 1000:
Additional diagnostic values of the drive.
For index 1:
Displays the value of the Control Unit that resulted in the STOP F.
For index 2:
Displays the value from the second channel that resulted in the STOP F.
Index:
[0] = Message value for CDC
[1] = Control Unit CDC actual value
[2] = Components CDC actual value
Dependency:
Refer to: C01711
Note:
The significance of the individual message values is described in message C01711.
CDC: Crosswise Data Comparison
For index 1, 2:
When Safety message C01711 with message value >= 1000 occurs, these indices are not supplied with values.
p9726
SI Motion user agreement selection/de-selection / SI Mtn UserAgr sel
VECTOR_G
Can be changed: U, T
Data type: Integer16
P-Group: Safety Integrated
Not for motor type: -
Min
0000 hex
Description:
Setting to select and de-select the user agreement.
Value:
0:
172:
Dependency:
Refer to: r9727
r9727
SI Motion user agreement inside the drive / SI Mtn UserAgr int
VECTOR_G
Can be changed: -
Data type: Integer16
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Displays the internal state of the user agreement.
Value = 0: User agreement is not set.
Value = AC hex: User agreement is set.
Dependency:
Refer to: p9726
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
[00 hex] De-select user agreement
[AC hex] Select user agreement
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
00AC hex
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 hex
Access level: 3
Func. diagram: 2822
Unit selection: -
Expert list: 1
Factory setting
-