Siemens G130 List Manual page 546

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r2129.0...15
CO/BO: Faults/alarms trigger word / F/A trigger word
All objects
Can be changed: -
Data type: Unsigned16
P-Group: Messages
Not for motor type: -
Min
-
Description:
Display and BICO output for the trigger signals of the faults/alarms set in p2128[0...15].
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
Dependency:
If the fault/alarm set in p2128[0...15] occurs, then the particular binector output r2129.0...15 is set.
Refer to: p2128
Note:
CO: r2129 = 0 --> None of the selected messages has occurred.
CO: r2129 > 0 --> At least one of the selected messages has occurred.
r2130[0...63]
Fault time received in days / t_fault recv days
All objects
Can be changed: -
Data type: Unsigned16
P-Group: Messages
Not for motor type: -
Min
-
Description:
Displays the system runtime in days when the fault occurred.
Dependency:
Refer to: r0945, r0947, r0948, r0949, r2109, r2114, r2133, r2136, r3115, r3120, r3122
Notice:
The time comprises r2130 (days) and r0948 (milliseconds).
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
r2131
CO: Actual fault code / Act fault code
All objects
Can be changed: -
Data type: Unsigned16
P-Group: Messages
Not for motor type: -
Min
-
Description:
Displays the code of the oldest active fault.
Dependency:
Refer to: r3131, r3132
Note:
0: No fault present.
546
Signal name
Trigger signal p2128[0]
Trigger signal p2128[1]
Trigger signal p2128[2]
Trigger signal p2128[3]
Trigger signal p2128[4]
Trigger signal p2128[5]
Trigger signal p2128[6]
Trigger signal p2128[7]
Trigger signal p2128[8]
Trigger signal p2128[9]
Trigger signal p2128[10]
Trigger signal p2128[11]
Trigger signal p2128[12]
Trigger signal p2128[13]
Trigger signal p2128[14]
Trigger signal p2128[15]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: 8070
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Access level: 3
Func. diagram: 8060
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: 8060
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS G130/G150
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents