Siemens G130 List Manual page 105

Hide thumbs Also See for G130:
Table of Contents

Advertisement

p0187[0...n]
Encoder 1 encoder data set number / Enc 1 EDS number
VECTOR_G
Can be changed: C1(4)
Data type: Unsigned8
P-Group: Data sets
Not for motor type: -
Min
0
Description:
Assign a drive data set (= index) the corresponding encoder data set (EDS) for encoder 1.
The value corresponds to the number of the assigned encoder data set.
Example:
Encoder 1 in drive data set 2 should be assigned encoder data set 0.
--> p0187[2] = 0
Note:
A value of 99 means that no encoder has been assigned to this drive data set (not configured).
p0188[0...n]
Encoder 2 encoder data set number / Enc 2 EDS number
VECTOR_G
Can be changed: C1(4)
Data type: Unsigned8
P-Group: Data sets
Not for motor type: -
Min
0
Description:
Assign a drive data set (= index) the corresponding encoder data set (EDS) for encoder 2.
The value corresponds to the number of the assigned encoder data set.
Example:
Encoder 2 in drive data set 2 should be assigned to encoder data set 1.
--> p0188[2] = 1
Note:
A value of 99 means that no encoder has been assigned to this drive data set (not configured).
p0189[0...n]
Encoder 3 encoder data set number / Enc 3 EDS number
VECTOR_G
Can be changed: C1(4)
Data type: Unsigned8
P-Group: Data sets
Not for motor type: -
Min
0
Description:
Assign a drive data set (= index) the corresponding encoder data set (EDS) for encoder 3.
The value corresponds to the number of the assigned encoder data set.
Note:
A value of 99 means that no encoder has been assigned to this drive data set (not configured).
r0192
Power unit firmware properties 1 / PU FW property 1
VECTOR_G, B_INF
Can be changed: -
Data type: Unsigned32
P-Group: Converter
Not for motor type: -
Min
-
Description:
Displays the properties supported by the power unit firmware.
Bit field:
Bit
00
01
02
03
05
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Signal name
Edge modulation possible
Free telegram can be selected
Smart mode possible for Active Line Module Yes
Safety Integrated possible for VECTOR
Thermal model expanded
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
99
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
99
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
99
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 4700, 8570
Unit selection: -
Expert list: 1
Factory setting
99
Access level: 3
Func. diagram: 4700, 8570
Unit selection: -
Expert list: 1
Factory setting
99
Access level: 3
Func. diagram: 4700, 8570
Unit selection: -
Expert list: 1
Factory setting
99
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
FP
-
-
-
-
-
105

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents