2 Parameters
2.2 List of parameters
p1092[0...n]
Skip speed 2 / n_skip 2
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Setpoints
Not for motor type: -
Min
0.000 [rpm]
Description:
Sets skip speed 2.
Dependency:
Refer to: p1091, p1093, p1094, p1101
Notice:
Skip bandwidths can also become ineffective as a result of the downstream limits in the setpoint channel.
p1093[0...n]
Skip speed 3 / n_skip 3
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Setpoints
Not for motor type: -
Min
0.000 [rpm]
Description:
Sets skip speed 3.
Dependency:
Refer to: p1091, p1092, p1094, p1101
Notice:
Skip bandwidths can also become ineffective as a result of the downstream limits in the setpoint channel.
p1094[0...n]
Skip speed 4 / n_skip 4
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Setpoints
Not for motor type: -
Min
0.000 [rpm]
Description:
Sets skip speed 4.
Dependency:
Refer to: p1091, p1092, p1093, p1101
Notice:
Skip bandwidths can also become ineffective as a result of the downstream limits in the setpoint channel.
p1098[0...n]
CI: Skip speed scaling / n_skip scal
VECTOR_G
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: Setpoints
Not for motor type: -
Min
-
Description:
Sets the signal source for scaling the skip speeds.
Dependency:
Refer to: p1091, p1092, p1093, p1094
322
Calculated: -
Dyn. index: DDS, p0180
Unit group: 3_1
Scaling: p2000
Max
210000.000 [rpm]
Calculated: -
Dyn. index: DDS, p0180
Unit group: 3_1
Scaling: p2000
Max
210000.000 [rpm]
Calculated: -
Dyn. index: DDS, p0180
Unit group: 3_1
Scaling: p2000
Max
210000.000 [rpm]
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: PERCENT
Max
-
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: 3050
Unit selection: p0505
Expert list: 1
Factory setting
0.000 [rpm]
Access level: 3
Func. diagram: 3050
Unit selection: p0505
Expert list: 1
Factory setting
0.000 [rpm]
Access level: 3
Func. diagram: 3050
Unit selection: p0505
Expert list: 1
Factory setting
0.000 [rpm]
Access level: 3
Func. diagram: 3050
Unit selection: -
Expert list: 1
Factory setting
1