Siemens G130 List Manual page 410

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p1531[0...n]
Power limit regenerative / P_max gen
VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
-100000.00 [kW]
Description:
Sets the regenerative power limit.
Dependency:
Refer to: p0500, p1530
Note:
The power limit is limited to 300% of the rated motor power.
For power units without regenerative feedback into the line supply, the regenerative power limit is pre-set to 30% of
the motoring power limit p1530 and in the ratio rated drive converter power to rated motor power. If a braking resistor
is connected to the DC link, then the power limit can be correspondingly increased.
r1533
Current limit torque-generating total / Iq_max total
VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: REL
Min
- [Arms]
Description:
Displays the maximum torque/force generating current as a result if all current limits.
r1536[0...1]
Current limit maximum torque-generating current / Isq_max
VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
- [Arms]
Description:
Displays the maximum limit for the torque-generating current component.
Index 0 indicates the signal limited by the Vdc controller.
Index:
[0] = Limited
[1] = Unlimited
r1537[0...1]
Current limit minimum torque-generating current / Isq_min
VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
- [Arms]
Description:
Displays the minimum limit for the torque-generating current component.
Index 0 indicates the signal limited by the Vdc controller.
Index:
[0] = Limited
[1] = Unlimited
410
Calculated:
CALC_MOD_LIM_REF
Dyn. index: DDS, p0180
Unit group: 14_5
Scaling: -
Max
-0.01 [kW]
Calculated: -
Dyn. index: -
Unit group: 6_2
Scaling: p2002
Max
- [Arms]
Calculated: -
Dyn. index: -
Unit group: 6_2
Scaling: p2002
Max
- [Arms]
Calculated: -
Dyn. index: -
Unit group: 6_2
Scaling: p2002
Max
- [Arms]
List Manual (LH2), 07/2016, A5E03263479A
Access level: 2
Func. diagram: 6640
Unit selection: p0505
Expert list: 1
Factory setting
-0.01 [kW]
Access level: 3
Func. diagram: 6640
Unit selection: p0505
Expert list: 1
Factory setting
- [Arms]
Access level: 4
Func. diagram: 6640, 6710
Unit selection: p0505
Expert list: 1
Factory setting
- [Arms]
Access level: 4
Func. diagram: 6640, 6710
Unit selection: p0505
Expert list: 1
Factory setting
- [Arms]
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents