Siemens G130 List Manual page 268

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p0820[0...n]
BI: Drive Data Set selection DDS bit 0 / DDS select., bit 0
VECTOR_G
Can be changed: C2(15), T
Data type: Unsigned32 / Binary
P-Group: Data sets
Not for motor type: -
Min
-
Description:
Sets the signal source to select the Drive Data Set, bit 0 (DDS, bit 0).
Dependency:
Refer to: r0051, r0837
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p0821[0...n]
BI: Drive Data Set selection DDS bit 1 / DDS select., bit 1
VECTOR_G
Can be changed: C2(15), T
Data type: Unsigned32 / Binary
P-Group: Data sets
Not for motor type: -
Min
-
Description:
Sets the signal source to select the Drive Data Set, bit 1 (DDS, bit 1).
Dependency:
Refer to: r0051, r0837
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p0822[0...n]
BI: Drive Data Set selection DDS bit 2 / DDS select., bit 2
VECTOR_G
Can be changed: C2(15), T
Data type: Unsigned32 / Binary
P-Group: Data sets
Not for motor type: -
Min
-
Description:
Sets the signal source to select the Drive Data Set, bit 2 (DDS, bit 2).
Dependency:
Refer to: r0051, r0837
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p0823[0...n]
BI: Drive Data Set selection DDS bit 3 / DDS select., bit 3
VECTOR_G
Can be changed: C2(15), T
Data type: Unsigned32 / Binary
P-Group: Data sets
Not for motor type: -
Min
-
Description:
Sets the signal source to select the Drive Data Set, bit 3 (DDS, bit 3).
Dependency:
Refer to: r0051, r0837
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
268
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: 8565, 8575
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 8565, 8570
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 8565
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 8565
Unit selection: -
Expert list: 1
Factory setting
0
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents