2.2 List of parameters
For bit 12:
Together with p7755, the bit is used to monitor write protection.
Bit = 1, if p7755 != 0 and write protection is active (p7760.0 = 1).
Bit = 0, if write protection was deactivated. p7755 is set to 0, and when write protection is activated again, bit 12
remains at 0.
p7761
Write protection / Write protection
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: Integer16
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
0
Description:
Setting for activating/deactivating the write protection for adjustable parameters.
Value:
0:
1:
Dependency:
Refer to: r7760
Notice:
While write protection is active, a download is prevented; however, it is still possible to restore the factory settings.
Note:
Parameters with the "WRITE_NO_LOCK" attributes are excluded from the write protection.
A product-specific list of these parameters is also available in the corresponding List Manual.
p7762
Write protection multi-master fieldbus system access behavior / Fieldbus acc_behav
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: Integer16
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
0
Description:
Sets the behavior for write protection when accessing via multi-master fieldbus systems (e.g. CAN, BACnet).
Value:
0:
1:
Dependency:
Refer to: r7760, p7761
p7763
KHP OEM exception list number of indices for p7764 / KHP OEM qty p7764
All objects
Can be changed: U, T
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
1
Description:
Sets the number of parameters for the OEM exception list (p7764[0...n]).
p7764[0...n], with n = p7763 - 1
Dependency:
Refer to: p7764
Note:
KHP: Know-How Protection
Even if know-how protection is set, parameters in this list can be read and written to.
772
Deactivate write protection
Activate write protection
Write access independent of p7761
Write access dependent on p7761
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
500
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1