2 Parameters
2.2 List of parameters
30:
80:
1011: Save in volatile memory, downloaded with p0976=1011
1012: Save in volatile memory, downloaded with p0976=1012
1013: Save in volatile memory, downloaded with p0976=1013
Dependency:
Refer to: p0976, p1960, p3845, r3996
Notice:
The Control Unit power supply may only be switched off after data has been saved (i.e. after data save has been
started, wait until the parameter again has the value 0).
Writing to parameters is inhibited while saving.
The progress while saving is displayed in r3996.
For p0977 = 30:
The original state when delivered is overwritten when executing this memory function.
Note:
Parameters saved with p0977 = 10, 11 or 12 can be downloaded again with p0976 = 10, 11 or 12.
The identification and maintenance data (I&M data, p8806 and following) are only saved for p0977 = 1.
p0978[0...n]
List of drive objects / List of the DO
CU_G130_PN,
Can be changed: C1(1)
CU_G150_PN,
Data type: Unsigned8
CU_G130_DP,
P-Group: Topology
CU_G150_DP
Not for motor type: -
Min
0
Description:
This parameter is an image of p0101 in conformance with PROFIdrive.
Parameters p0101 and p0978 contain the following information:
1) The same number of drive objects
2) The same drive objects
In this sense, they are consistent.
Difference between p0101 and p0978:
p0978 can be re-sorted and a zero inserted in order to identify those drive objects that participate in the process data
exchange and to define their sequence in the process data exchange. Drive objects that are listed after the first zero,
are excluded from the process data exchange.
For p0978, in addition, the value 255 can be inserted a multiple number of times.
p0978[n] = 255 means: The drive object is visible for the PROFIBUS master and is empty (without any actual process
data exchange). This allows cyclic communications of a PROFIBUS master with unchanged configuring to the drive
units with a lower number of drive objects.
Dependency:
Refer to: p0101, p0971, p0977
Note:
p0978 cannot be changed when the drive system is first commissioned. The reason for this is that at this time the
actual topology has still not been acknowledged (p0099 is still not equal to r0098 and p0009 is set to 0).
r0979[0...30]
PROFIdrive encoder format / PD encoder format
VECTOR_G
Can be changed: -
Data type: Unsigned32
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the actual position encoder used according to PROFIdrive.
Index:
[0] = Header
[1] = Type encoder 1
[2] = Resolution enc 1
[3] = Shift factor G1_XIST1
[4] = Shift factor G1_XIST2
[5] = Distinguishable revolutions encoder 1
[6...10] = Reserved
[11] = Type encoder 2
[12] = Resolution enc 2
302
State when delivered, save in non-volatile memory as setting 30
Save in non-volatile memory time-optimized (reserved)
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
255
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
List Manual (LH2), 07/2016, A5E03263479A
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
[0] 1
[1...24] 0
Access level: 3
Func. diagram: 4704
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS G130/G150