r3662[0...n]
CO: VSM input line supply voltage u2 - u3 / VSM inp u2-u3
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: -
Min
- [V]
Description:
Displays the input voltage between phases L2 and L3 for the Voltage Sensing Module (VSM).
Dependency:
Refer to: p3660
Note:
X521.1 or X522.1: Connection of L1
X521.2 or X522.2: Connection of L2
X521.3 or X522.3: Connection of L3
r3664[0...n]
CO: VSM temperature evaluation status / VSM temp status
VECTOR_G
Can be changed: -
Data type: Unsigned16
P-Group: Terminals
Not for motor type: -
Min
-
Description:
Displays the status of the temperature evaluation using the Voltage Sensing Module (VSM).
This displays whether the temperature actual value has exceeded the alarm/fault threshold.
Bit field:
Bit
00
01
Dependency:
Refer to: p3665, r3666, p3667, p3668
p3665[0...n]
VSM temperature evaluation sensor type / VSM TempSensorType
VECTOR_G
Can be changed: T
Data type: Integer16
P-Group: Closed-loop control
Not for motor type: -
Min
0
Description:
Setting of the temperature sensor for the Voltage Sensing Module (VSM).
The temperature sensor is connected to terminals X520.5 and X520.6 of the VSM.
Value:
0:
1:
2:
6:
r3666[0...n]
CO: VSM temperature actual value / VSM Temp_ActVal
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: -
Min
- [°C]
Description:
Display and connector output for the temperature actual value of a temperature sensor connected to a Voltage
Sensing Module (VSM).
Prerequisite:
A KTY/ PT1000 temperature sensor is connected, and correspondingly 3665 is set = 2, 6.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Signal name
Alarm is present
Fault is present
No sensor
PTC
KTY84
PT1000
Calculated: -
Dyn. index: p0150
Unit group: 5_3
Scaling: p2001
Max
- [V]
Calculated: -
Dyn. index: p0150
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Calculated: -
Dyn. index: p0150
Unit group: -
Scaling: -
Max
6
Calculated: -
Dyn. index: p0150
Unit group: 21_1
Scaling: p2006
Max
- [°C]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [V]
Access level: 3
Func. diagram: 9886
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
Access level: 3
Func. diagram: 9886
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 9886
Unit selection: p0505
Expert list: 1
Factory setting
- [°C]
FP
-
-
611

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents