2 Parameters
2.2 List of parameters
104:
107:
108:
111:
134:
136:
166:
222:
264:
283:
600:
10000: Motor with DRIVE-CLiQ
10001: Motor with DRIVE-CLiQ 2nd data set
Dependency:
Motors, selection 206, 236, 237 cannot be operated (also not as motor with DRIVE-CLiQ).
p0300 = 5 cannot be selected with SINAMICS G.
When the motor type is changed, the code number in p0301 may be reset to 0.
p0300 = 12 can only be selected for p0100 = 1 (NEMA).
When selecting p0300 = 10 ... 19, parameters p0335, p0626, p0627, and p0628 of the thermal motor model are pre-
assigned as a function of p0307 and p0311.
When selecting a 1FW4 motor – if the motor database permits this – when exiting commissioning, then p1750.5 is
automatically set. This is the reason that after exiting commissioning, all parameters must be saved and a warm
restart must be initiated (e.g. p0009 = 30, p0976 = 3).
Refer to: p0301
Caution:
A permanent-magnet synchronous motor cannot be operated with an SSI encoder without HTL/TTL track.
A separately excited synchronous motor can only be operated with an SSI encoder if this is used as the second
encoder and an HTL/TTL encoder is used as the first encoder.
Notice:
If a catalog motor is selected (p0300 >= 100) and an associated motor code number (p0301), then the parameters
that are associated with this list cannot be changed (write protection). The write protection is canceled if the motor
type p0300 is set to a non-Siemens motor that matches p0301 (e.g. p0300 = 2 for p0301 = 2xxxx). Write protection is
automatically canceled when the results of motor data identification are copied to the motor parameters.
The motor type of a catalog motor corresponds to the upper three digits of the code number or the following
assignment (if the particular motor type is listed):
Type/code number ranges
100 / 100xx, 110xx, 120xx, 130xx, 140xx, 150xx, 160xx, 170xx, 180xx, 190xx
101 / 101xx
102 / 102xx, 122xx
104 / 104xx, 114xx, 124xx
107 / 107xx, 117xx, 127xx
108 / 108xx, 118xx, 128xx, 138xx, 148xx, 158xx
134 / 134xx, 144xx, 154xx
136 / 136xx, 146xx, 156xx
166 / 166xx, 176xx, 186xx
264 / 264xx, 274xx, 284xx, 294xx
283 / 283xx, 293xx
For OEM motors:
111 / 111xx, 112xx, 113xx
222 / 222xx, 223xx, 224xx
For 1PQ8 motors (p0300 = 18) the fan type p0335 should be set to 5.
Note:
With p0300 = 10000, for a motor with DRIVE-CLiQ, the motor parameters are automatically downloaded, with p0300
= 10001, the motor parameters of a second data set (if available).
If a motor type has not been selected (p0300 = 0), then the drive commissioning routine cannot be exited.
A motor type with a value above p0300 >= 100 describes motors for which a motor parameter list exists.
Motor types with a value below p0300 < 100 correspond to the selection of a third-party motor. When appropriately
selected, this means that the motor parameters are pre-assigned the settings for a third-party motor.
This also applies for parameters for a motor with DRIVE-CLiQ. In this case p0300 can only be set to p0300 = 10000
or 10001 (read motor parameters) or to the corresponding non-Siemens motor (first digit of the motor code number)
in order to be able to cancel the write protection.
130
1PH4 induction motor
1PH7 induction motor
1PH8 induction motor
xxxx induction motor OEM
1PM4 induction motor
1PM6 induction motor
1PL6 induction motor
xxxx synchronous motor OEM
1FW4 synchronous motor
1FW3 synchronous motor
1FP1 standard reluctance motor
SINAMICS G130/G150