Siemens G130 List Manual page 998

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r9780
SI monitoring clock cycle (Control Unit) / SI monitor_clck CU
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
- [ms]
Description:
Displays the clock cycle time for the Safety Integrated Basic Functions on the Control Unit.
Dependency:
Refer to: r0110, p0115, r9880
Note:
Information regarding the relationship between monitoring clock cycle and response times can be found in the
following references:
- SINAMICS S120 Function Manual Safety Integrated
- technical documentation for the particular product
r9781[0...1]
SI checksum to check changes (Control Unit) / SI chg chksm CU
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
P-Group: Safety Integrated
CU_G150_DP
Not for motor type: -
Min
-
Description:
Displays the checksum for tracking changes for Safety Integrated.
These are additional checksums that are created to track changes (fingerprint for the "safety logbook" functionality) to
safety parameters (that are relevant for checksums).
Index:
[0] = SI checksum to track functional changes
[1] = SI checksum to track hardware-specific changes
Dependency:
Refer to: p9601, p9729, p9799
Refer to: F01690
r9782[0...1]
SI time stamps to check changes (Control Unit) / SI chg t CU
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: FloatingPoint32
CU_G130_DP,
P-Group: Safety Integrated
CU_G150_DP
Not for motor type: -
Min
- [h]
Description:
Displays the time stamps for the checksums for tracking changes for Safety Integrated.
The time stamps for the checksums for tracking changes (fingerprint for the "safety logbook" functionality) made to
safety parameters are saved in parameters p9781[0] and p9781[1].
Index:
[0] = SI time stamp for checksum to track functional changes
[1] = SI time stamp for checksum to track hardware-specific changes
Dependency:
Refer to: p9601, p9729, p9799
Refer to: F01690
998
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [h]
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: 2802
Unit selection: -
Expert list: 1
Factory setting
- [ms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [h]
SINAMICS G130/G150