Siemens G130 List Manual page 710

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
[2] = Trace 0 PINx with DO Id and chart Id
[3] = Trace 0 PINx with block Id and PIN Id
[4] = Trace 1 PINy with DO Id and chart Id
[5] = Trace 1 PINy with block Id and PIN Id
p4736[0...5]
Trace record signal 6 / Trace record sig 6
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
P-Group: Trace and function generator
CU_G150_DP
Not for motor type: -
Min
-
Description:
Selects the seventh signal to be traced.
Index:
[0] = Trace 0 parameter in BICO format
[1] = Trace 1 parameter in BICO format
[2] = Trace 0 PINx with DO Id and chart Id
[3] = Trace 0 PINx with block Id and PIN Id
[4] = Trace 1 PINy with DO Id and chart Id
[5] = Trace 1 PINy with block Id and PIN Id
p4737[0...5]
Trace record signal 7 / Trace record sig 7
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
P-Group: Trace and function generator
CU_G150_DP
Not for motor type: -
Min
-
Description:
Selects the eighth signal to be traced.
Index:
[0] = Trace 0 parameter in BICO format
[1] = Trace 1 parameter in BICO format
[2] = Trace 0 PINx with DO Id and chart Id
[3] = Trace 0 PINx with block Id and PIN Id
[4] = Trace 1 PINy with DO Id and chart Id
[5] = Trace 1 PINy with block Id and PIN Id
r4740[0...16383]
Trace 0 trace buffer signal 0 floating point / Trace 0 rec sig 0
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: FloatingPoint32
CU_G130_DP,
P-Group: Trace and function generator
CU_G150_DP
Not for motor type: -
Min
-
Description:
Displays the trace buffer (record buffer) for trace 0 and signal 0.
The trace (record) buffer is sub-divided into memory banks, each containing 16384 values. Parameter p4795 can be
used to toggle between the individual banks.
Example A:
The first 16384 values of signal 0, trace 0 are to be read out.
In this case, memory bank 0 is set with p4795 = 0. The first 16384 values can now be read out using r4740[0] to
r4740[16383].
Example B:
The values 16385 to 32768 from signal 0, trace 0 are to be read out.
In this case, memory bank 1 is set with p4795 = 1. The values can now be read out in r4740[0] to r4740[16383].
Dependency:
Refer to: p4795
710
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents