Siemens G130 List Manual page 441

Hide thumbs Also See for G130:
Table of Contents

Advertisement

p1710[0...n]
Current controller adaptation in-line axis starting point Kp / Id_adapt pt Kp
VECTOR_G (n/M)
Can be changed: C2(3), U, T
Data type: FloatingPoint32
P-Group: Motor
Not for motor type: ASM, PMSM, SESM,
REL
Min
0.00 [Arms]
Description:
Sets the starting point of the current-dependent current controller adaptation where the current controller gain p1720
is effective.
Dependency:
Refer to: p1720
Notice:
When selecting a catalog motor (p0301), this parameter is automatically pre-assigned and is write protected.
Information in p0300 should be carefully observed when removing write protection.
Note:
For p1712 = 100 % or p1402.2 = 0, the current controller adaptation is disabled and p1720 is effective over the entire
range.
p1711[0...n]
Current ctrl adaptation in-line axis starting point Kp adapted / Id_adap pt Kp adap
VECTOR_G (n/M)
Can be changed: C2(3), U, T
Data type: FloatingPoint32
P-Group: Motor
Not for motor type: ASM, PMSM, SESM,
REL
Min
0.00 [Arms]
Description:
Sets the starting point of the current-dependent current controller adaptation where the adapted current controller
gain p1720 x p1712 is effective.
Dependency:
Refer to: p1710, p1712, p1720
Notice:
When selecting a catalog motor (p0301), this parameter is automatically pre-assigned and is write protected.
Information in p0300 should be carefully observed when removing write protection.
Note:
For p1712 = 100 % or p1402.2 = 0, the current controller adaptation is disabled and p1720 is effective over the entire
range.
p1712[0...n]
Current controller adaptation in-line axis p gain adaptation / Id_adapt Kp adapt
VECTOR_G (n/M)
Can be changed: C2(3), U, T
Data type: FloatingPoint32
P-Group: Motor
Not for motor type: ASM, PMSM, SESM,
REL
Min
0.00 [%]
Description:
Sets the factor for the current controller P gain in the adaptation range (d-current > p1711).
The value is referred to p1720.
Dependency:
Refer to: p1710, p1711, p1720
Notice:
When selecting a catalog motor (p0301), this parameter is automatically pre-assigned and is write protected.
Information in p0300 should be carefully observed when removing write protection.
Note:
For p1712 = 100 % or p1402.2 = 0, the current controller adaptation is disabled and p1720 is effective over the entire
range.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: CALC_MOD_REG
Dyn. index: MDS, p0130
Unit group: -
Scaling: -
Max
6000.00 [Arms]
Calculated: CALC_MOD_REG
Dyn. index: MDS, p0130
Unit group: -
Scaling: -
Max
6000.00 [Arms]
Calculated: CALC_MOD_REG
Dyn. index: MDS, p0130
Unit group: -
Scaling: -
Max
1000.00 [%]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.00 [Arms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.00 [Arms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
100.00 [%]
441

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents