Siemens G130 List Manual page 525

Hide thumbs Also See for G130:
Table of Contents

Advertisement

r2076[0...11]
IF1 PROFIdrive diagnostics telegram offset PZD send / IF1 diag offs send
ENC
Can be changed: -
Data type: Unsigned16
P-Group: Communications
Not for motor type: -
Min
-
Description:
Displays the PZD byte offset in the PROFIdrive send telegram (controller input).
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
[8] = PZD 9
[9] = PZD 10
[10] = PZD 11
[11] = PZD 12
Note:
IF1: Interface 1
Value range:
0 - 242: Byte offset
65535: Not assigned
r2077[0...15]
PROFIBUS diagnostics peer-to-peer data transfer addresses / PB diag peer addr
CU_G130_DP,
Can be changed: -
CU_G150_DP
Data type: Unsigned8
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the addresses of the slaves (peers) where peer-to-peer data transfer has been configured via PROFIBUS.
p2079
IF1 PROFIdrive PZD telegram selection extended / IF1 PZD telegr ext
CU_G130_PN,
Can be changed: T
CU_G150_PN,
Data type: Integer16
CU_G130_DP,
P-Group: Communications
CU_G150_DP
Not for motor type: -
Min
390
Description:
Sets the send and receive telegram.
Contrary to p0922, a telegram can be selected using p2079 and subsequently expanded.
Value:
390:
391:
392:
393:
394:
395:
999:
Note:
For p0922 < 999 the following applies:
p2079 has the same value and is inhibited. All of the interconnections and extensions contained in the telegram are
inhibited.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
SIEMENS telegram 390, PZD-2/2
SIEMENS telegram 391, PZD-3/7
SIEMENS telegram 392, PZD-3/15
SIEMENS telegram 393, PZD-4/21
SIEMENS telegram 394, PZD-3/3
SIEMENS telegram 395, PZD-4/25
Free telegram configuration with BICO
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
999
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 2410
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
999
525

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents