2 Parameters
2.2 List of parameters
p4641[0...2]
OEM encoder diagnostic signal selection / OEM enc diag sel
VECTOR_G
Can be changed: U, T
Data type: Unsigned16
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the trace functionality for OEM encoder manufacturers.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
p4642
Test function encoder fault / Test encoder fault
VECTOR_G
Can be changed: U, T
Data type: Unsigned8
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Test function to initiate an encoder fault
For a 0/1 transition, an encoder fault is output at the currently used motor encoder.
For a 1/0 transition and an alarm acknowledgment, the encoder fault that was issued is cleared.
Notice:
It is not permissible that a data set is switched over between issuing and deleting an encoder fault.
p4650
Encoder functional reserve component number / Enc fct_res num
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: Unsigned16
CU_G130_DP,
P-Group: Displays, signals
CU_G150_DP
Not for motor type: -
Min
0
Description:
Sets the component number (p0141) of the encoder whose functional reserve is to be displayed (r4651).
Dependency:
Refer to: r4651
r4651[0...3]
Encoder functional reserve / Enc fct_reserve
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: FloatingPoint32
CU_G130_DP,
P-Group: Displays, signals
CU_G150_DP
Not for motor type: -
Min
- [%]
Description:
Displays the functional reserve of the encoder selected via p4650.
0 ... 25 %:
The function limit has been reached. A service is recommended.
26 ... 100 %:
The encoder is working in the specified range.
Index:
[0] = Function reserve 1
[1] = Function reserve 2
[2] = Function reserve 3
[3] = Function reserve 4
Dependency:
Refer to: p4650
686
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
65535
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
255
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
399
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [%]
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [%]