2 Parameters
2.2 List of parameters
p0571[0...49]
Inhibit list motor/closed-loop control parameter calculation / Inhib list calc
VECTOR_G
Can be changed: U, T
Data type: Integer16
P-Group: Applications
Not for motor type: -
Min
0
Description:
The inhibit list contains parameters that should be withdrawn from the automatic motor and closed-loop control
parameter calculation (p0340, p0578).
Value:
0:
600:
640:
1082: Maximum speed
1460: Speed controller P gain
1462: Speed controller integral time
1470: Speed controller P gain encoderless
1472: Speed controller integral time encoderless
1520: Torque limit upper/motoring
1521: Torque limit lower/regenerative
1530: Power limit motoring
1531: Power limit regenerative
1590: Flux controller P gain
1592: Flux controller integral time
2141: Speed threshold 1
2142: Hysteresis speed 1
Note:
p0570 defines the number of entries (starting at index 0) for which the inhibit should apply. p0572 can be used to
define for which drive data sets the inhibit list should apply.
If a motor data set is entered into a parameter number, then this is not overwritten as soon as only one drive data set
refers to the motor data set (p0186).
p0572[0...n]
Activate/deactivate inhibit list / Inh_list act/deact
VECTOR_G
Can be changed: U, T
Data type: Integer16
P-Group: Applications
Not for motor type: -
Min
0
Description:
Setting for activating/deactivating the inhibit list.
Depending on the setting, the parameters of the inhibit list (p0571) should be overwritten when calculating the motor
and closed-loop control parameters for the particular drive data set (DDS).
Value:
0:
1:
Note:
If value = 0:
The automatic calculation (p0340, p0578) also overwrites the parameters of the inhibit list (p0571).
If value = 1:
The automatic calculation (p0340, p0578) does not overwrite the parameters of the inhibit list (p0571).
228
No parameter
Motor temperature sensor
Current limit
No
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2142
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
1
List Manual (LH2), 07/2016, A5E03263479A
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0