2 Parameters
2.2 List of parameters
p2039
Select debug monitor interface / Debug monit select
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: Unsigned16
CU_G130_DP,
P-Group: Communications
CU_G150_DP
Not for motor type: -
Min
0
Description:
Sets the serial interface for the debug monitor.
The serial interface for the debug monitor is COM1 (X140) or COM2 (internal).
Value = 0: COM2 (internal)
Value = 1: COM1 (X140), commissioning protocol is deactivated
Value = 2: COM2 (internal)
Value = 3: Reserved
p2040
Fieldbus interface monitoring time / Fieldbus t_monit
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: FloatingPoint32
CU_G130_DP,
P-Group: Communications
CU_G150_DP
Not for motor type: -
Min
0 [ms]
Description:
Sets the monitoring time to monitor the process data received via the fieldbus interface.
If no process data is received within this time, then an appropriate message is output.
Dependency:
Refer to: p2030
Note:
The parameter is only relevant for the setting of the following fieldbus protocols.
- USS (X140) (p2030 = 6)
- Modbus TCP (p2030 = 13)
Value = 0: Monitoring is deactivated.
p2042
PROFIBUS Ident Number / PB ident No.
CU_G130_DP,
Can be changed: T
CU_G150_DP
Data type: Integer16
P-Group: Communications
Not for motor type: -
Min
0
Description:
Sets the PROFIBUS ident number (PNO-ID).
SINAMICS can be operated with various identities on PROFIBUS. This allows the use of a PROFIBUS GSD that is
independent of the device (e.g. PROFIdrive VIK-NAMUR with ident number 3AA0 hex).
Value:
0:
1:
Note:
Every change only becomes effective after a POWER ON.
500
SINAMICS
VIK-NAMUR
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
3
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1999999 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
List Manual (LH2), 07/2016, A5E03263479A
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 9310
Unit selection: -
Expert list: 1
Factory setting
100 [ms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0