2 Parameters
2.2 List of parameters
r4104.0...1
BO: TM31 temperature evaluation status / TM31 temp status
TM31
Can be changed: -
Data type: Unsigned16
P-Group: Terminals
Not for motor type: -
Min
-
Description:
Display and binector output for the status for the Terminal Module 31 (TM31).
Bit field:
Bit
00
01
Dependency:
Refer to: p4102
r4105[0...3]
CO: TM120 temperature actual value / TM120 temp_act val
TM120
Can be changed: -
Data type: FloatingPoint32
P-Group: Terminals
Not for motor type: -
Min
- [°C]
Description:
Displays the temperature actual value for the Terminal Module 120 (TM120)
Index:
[0] = Temperature channel 0
[1] = Temperature channel 1
[2] = Temperature channel 2
[3] = Temperature channel 3
Dependency:
For sensor type "PTC thermistor" and "Bimetallic NC contact" (p4100 = 1, 4), the following applies:
- below the nominal response temperature, r4105 = -50°C.
- above the nominal response temperature, r4105 = 250 °C.
For sensor type "KTY84" "PT1000" (p4100 = 2, 6), the following applies:
- the displayed value corresponds to the temperature actual value.
Refer to: p4100
Note:
r4105[0...3] = -300 °C is displayed in the following cases:
- temperature actual value invalid (F35920 ... F35923 output).
- no sensor selected (p4100[0...3] = 0).
The temperature sensor is connected to the following terminals:
X521.2(+), X521.1(-) = channel 0
X521.4(+), X521.3(-) = channel 1
X521.6(+), X521.5(-) = channel 2
X521.8(+), X521.7(-) = channel 3
r4105[0...11]
CO: TM150 temperature actual value / TM150 temp_act val
TM150
Can be changed: -
Data type: FloatingPoint32
P-Group: Terminals
Not for motor type: -
Min
- [°C]
Description:
Displays the temperature actual value for the Terminal Module 150 (TM150)
Index:
[0] = Temperature channel 0
[1] = Temperature channel 1
[2] = Temperature channel 2
[3] = Temperature channel 3
[4] = Temperature channel 4
674
Signal name
Alarm is present
Fault is present
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: p2006
Max
- [°C]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: p2006
Max
- [°C]
List Manual (LH2), 07/2016, A5E03263479A
Access level: 1
Func. diagram: 9549, 9576
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
Access level: 1
Func. diagram: 8016, 9605,
9606
Unit selection: -
Expert list: 1
Factory setting
- [°C]
Access level: 1
Func. diagram: 9626, 9627
Unit selection: -
Expert list: 1
Factory setting
- [°C]
SINAMICS G130/G150