Siemens G130 List Manual page 1023

Hide thumbs Also See for G130:
Table of Contents

Advertisement

p9938
DRIVE-CLiQ detailed diagnostics configuration / DQ diag config
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: Integer16
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
0
Description:
Sets the configuration for the DRIVE-CLiQ detailed diagnostics (r9943).
Using the detailed diagnostics, it is possible to investigate data transfer errors on an individual connection, selected
using p9942.
Value:
0:
1:
2:
3:
4:
5:
6:
Dependency:
The functions in p9938 can only be set for p9937.0 = 0.
Refer to: r9936, p9937, p9939, p9942
Notice:
If value = 0:
- detailed diagnostics is inactive.
- the error counter is active (r9936).
If value > 0:
- the error counter is inactive (r9936).
- the detailed diagnostics as configured is active (r9943).
p9939
DRIVE-CLiQ detailed diagnostics time interval / DQ detail t_interv
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: FloatingPoint32
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
1 [s]
Description:
Sets the time interval for recording the error counter in r9943.
Dependency:
Refer to: r9936, p9938, p9942, r9943
p9941
Target topology feature delete all components / Feature delete
CU_G130_PN,
Can be changed: C1(1)
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
P-Group: Topology
CU_G150_DP
Not for motor type: -
Min
0
Description:
For p9941 =1, the serial numbers of all components in the target topology are deleted (zero is written).
Through activation and deactivation this enables the actual topology components to be newly assigned to the target
topology components.
Note:
p9941 is automatically set to 0 at the end of the operation.
A warm restart is triggered automatically after p0009 = 0.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Inactive
Sum send and receive errors
Only send errors
Only receive errors
Siemens internal
Siemens internal
Siemens internal
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
6
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
3600 [s]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
2 Parameters
2.2 List of parameters
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1 [s]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0