Siemens G130 List Manual page 200

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r0475
Gx_XIST1 coarse position safe most significant bit / Gx_XIST1 safe MSB
ENC
Can be changed: -
Data type: Unsigned16
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the bit number for the safe most significant bit (MSB) of the Gx_XIST1 coarse position.
Note:
MSB: Most Significant Bit
r0477[0...2]
CO: Measuring gear position difference / Meas gear pos diff
VECTOR_G
Can be changed: -
Data type: Integer32
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the position difference before the measuring gear between switching off and switching on.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency:
Refer to: F31501, F32501, F33501
Note:
The increments are displayed in the format the same as r0483. The position difference should be read in encoder
increments.
r0477
CO: Measuring gear position difference / Meas gear pos diff
ENC
Can be changed: -
Data type: Integer32
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the position difference before the measuring gear between switching off and switching on.
Dependency:
Refer to: F31501, F32501, F33501
Note:
The increments are displayed in the format the same as r0483. The position difference should be read in encoder
increments.
r0479[0...2]
CO: Diagnostics encoder position actual value Gn_XIST1 / Diag Gn_XIST1
VECTOR_G
Can be changed: -
Data type: Integer32
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Display and connector output for the encoder actual position value Gn_XIST1 according to PROFIdrive for
diagnostics.
In contrast to r0482, the value is updated in each DRIVE-CLiQ basic clock cycle and displayed with sign.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
200
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: 4704
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150