p0573
Inhibit automatic reference value calculation / Inhibit calc
VECTOR_G, B_INF
Can be changed: U, T
Data type: Integer16
P-Group: Applications
Not for motor type: -
Min
0
Description:
Setting to inhibit the calculation of reference parameters (e.g. p2000) when automatically calculating the motor and
closed-loop control parameters (p0340, p3900).
Value:
0:
1:
Notice:
The inhibit for the reference value calculation is canceled when new motor parameters (e.g. p0305) are entered and
only one drive data set exists (p0180 = 1). This is the case during initial commissioning.
Once the motor and control parameters have been calculated (p0340, p3900), the inhibit for the reference value
calculation is automatically re-activated.
Note:
If value = 0:
The automatic calculation (p0340, p3900) overwrites the reference parameters.
If value = 1:
The automatic calculation (p0340, p3900) does not overwrite the reference parameters.
p0578[0...n]
Calculate technology-dependent parameters / Calc tec par
VECTOR_G
Can be changed: C2(5), T
Data type: Integer16
P-Group: Applications
Not for motor type: -
Min
0
Description:
This parameter is used to calculate all parameters that depend on the technology of the application (p0500).
All of the parameters are calculated that can also be determined using p0340 = 5.
Value:
0:
1:
Note:
At the end of the calculations, p0578 is automatically set to 0.
p0595
Technological unit selection / Tech unit select
VECTOR_G
Can be changed: C2(5)
(Tech_ctrl)
Data type: Integer16
P-Group: Applications
Not for motor type: -
Min
1
Description:
Selects the units for the parameters of the technology controller.
For p0595 = 1, 2, the reference quantity set in p0596 is not active.
Value:
1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
No
Yes
No calculation
Complete calculation
%
1 referred no dimensions
bar
°C
Pa
ltr/s
m³/s
ltr/min
m³/min
ltr/h
m³/h
kg/s
kg/min
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
32
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
229