Siemens G130 List Manual page 997

Hide thumbs Also See for G130:
Table of Contents

Advertisement

r9776.0...3
BO: SI diagnostics / SI diag
VECTOR_G
Can be changed: -
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
The parameter is used for diagnostics.
Bit field:
Bit
00
01
02
03
Dependency:
Refer to: r9793
Note:
For bit 00 = 1:
At least one Safety parameter has been changed that will only take effect after a POWER ON.
For bit 01 = 1:
Safety functions (basic functions or extended functions) have been enabled and are active.
For bit 02 = 1:
A safety-relevant component has been replaced. Data save required (p0977 = 1 or p0971 = 1 or "copy RAM to
ROM").
For bit 03 = 1:
A safety-relevant component has been replaced. Acknowledge (p9702 = 29) and save (p0977 = 1 or p0971 = 1 or
"Copy RAM to ROM") required.
r9776.0...2
BO: SI diagnostics / SI diag
TM54F_MA
Can be changed: -
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
The parameter is used for diagnostics.
Bit field:
Bit
00
01
02
Dependency:
Refer to: r9793
Note:
For bit 00 = 1:
At least one Safety parameter has been changed that will only take effect after a POWER ON.
For bit 01 = 1:
Safety functions (basic functions or extended functions) have been enabled and are active.
For bit 02 = 1:
A safety-relevant component has been replaced. Data save required (p0977 = 1 or p0971 = 1 or "copy RAM to
ROM").
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Signal name
Safety parameter changed POWER ON
required
Safety functions enabled
Safety component replaced and data save
required
Safety component replaced and
acknowledge/save required
Signal name
Safety parameter changed POWER ON
required
Safety functions enabled
Safety component replaced and data save
required
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
FP
-
-
-
-
FP
-
-
-
997

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents