Siemens G130 List Manual page 819

Hide thumbs Also See for G130:
Table of Contents

Advertisement

p8713[0...3]
CAN Receive Mapping for RPDO 4 / Mapping RPDO 4
VECTOR_G (CAN)
Can be changed: C1(3), T
Data type: Unsigned32
P-Group: Communications
Not for motor type: -
Min
0000 hex
Description:
Sets the mapping parameters for CANopen Receive Process Data Object 4 (RPDO 4).
Index:
[0] = Mapped object 1
[1] = Mapped object 2
[2] = Mapped object 3
[3] = Mapped object 4
Note:
Corresponds to the CANopen object 1603 hex + 40 hex * x (x: Drive number 0 ... 7).
Dummy mapping not supported.
The parameter can only be written online when the associated COB ID in p870x is set as invalid.
p8714[0...3]
CAN Receive Mapping for RPDO 5 / Mapping RPDO 5
VECTOR_G (CAN)
Can be changed: C1(3), T
Data type: Unsigned32
P-Group: Communications
Not for motor type: -
Min
0000 hex
Description:
Sets the mapping parameters for CANopen Receive Process Data Object 5 (RPDO 5).
Index:
[0] = Mapped object 1
[1] = Mapped object 2
[2] = Mapped object 3
[3] = Mapped object 4
Note:
Corresponds to the CANopen object 1604 hex + 40 hex * x (x: Drive number 0 ... 7).
Dummy mapping not supported.
The parameter can only be written online when the associated COB ID in p870x is set as invalid.
p8715[0...3]
CAN Receive Mapping for RPDO 6 / Mapping RPDO 6
VECTOR_G (CAN)
Can be changed: C1(3), T
Data type: Unsigned32
P-Group: Communications
Not for motor type: -
Min
0000 hex
Description:
Sets the mapping parameters for CANopen Receive Process Data Object 6 (RPDO 6).
Index:
[0] = Mapped object 1
[1] = Mapped object 2
[2] = Mapped object 3
[3] = Mapped object 4
Note:
Corresponds to the CANopen object 1605 hex + 40 hex * x (x: Drive number 0 ... 7).
Dummy mapping not supported.
The parameter can only be written online when the associated COB ID in p870x is set as invalid.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
FFFF FFFF hex
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
FFFF FFFF hex
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
FFFF FFFF hex
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 9204, 9206
Unit selection: -
Expert list: 1
Factory setting
0000 hex
Access level: 3
Func. diagram: 9204
Unit selection: -
Expert list: 1
Factory setting
0000 hex
Access level: 3
Func. diagram: 9204
Unit selection: -
Expert list: 1
Factory setting
0000 hex
819

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents