Siemens G130 List Manual page 878

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
Note:
Activation of the FTP server becomes effective immediately.
Deactivation only becomes effective after POWER ON of the Control Unit.
Before commissioning the system for the first time, the FTP server is activated independent of the parameter setting.
r8909
PN device ID / PN device ID
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: Unsigned16
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
-
Description:
Displays the PROFINET Device ID.
Every SINAMICS device type has its own PROFINET Device ID and its own PROFINET GSD.
Note:
List of the SINAMICS Device IDs:
0501 hex: S120/S150
0504 hex: G130/G150
050A hex: DC MASTER
050C hex: MV
050F hex: G120P
0510 hex: G120C
0511 hex: G120 CU240E-2
0512 hex: G120D
0513 hex: G120 CU250S-2 Vector
0514 hex: G110M
r8910[0...239]
IE Name of Station actual / IE Name Stat act
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: Unsigned8
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
-
Description:
Displays the actual station name for the Industrial Ethernet interface (X127) on the Control Unit.
r8911[0...3]
IE IP address actual / IE IP addr act
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: Unsigned8
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
0
Description:
Displays the actual IP address for the Industrial Ethernet interface (X127) on the Control Unit.
r8912[0...3]
IE def gateway actual / IE Def Gateway act
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: Unsigned8
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
0
Description:
Displays the actual default gateway for the Industrial Ethernet interface (X127) on the Control Unit.
878
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
255
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
255
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents