Siemens G130 List Manual page 980

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
08
09
10
11
12
13
15
16
18
19
20
21
28
29
30
31
Note:
For r9719.0 and r9719.1:
These two bits must be considered together.
- if SOS/SLS (SBH/SG) is de-selected using bit 0, then assignment of bit 1 is irrelevant.
- if SOS/SLS (SBH/SG) is selected using bit 0, then a changeover is made between SOS (SBH) and SLS (SG) using
bit 1.
SLP: Safely Limited Position / SE: Safe software limit switches
SLS: Safely Limited Speed / SG: Safely reduced speed
SOS: Safe Operating Stop / SBH: Safe operating stop
SDI: Safe Direction (safe motion direction)
r9720.0...28
CO/BO: SI Motion control signals integrated in the drive / SI Mtn integ STW
VECTOR_G
Can be changed: -
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Control signals for safety-relevant motion monitoring functions integrated in the drive.
Bit field:
Bit
00
01
02
03
04
06
07
09
10
12
13
19
24
25
26
27
28
Note:
This parameter is only supplied with actual values in the case of Safety Integrated Extended Functions. For Safety
Integrated Basic Functions (SBC, SS1, STO), the value is equal to zero.
980
Gearbox selection bit 0
Gearbox selection bit 1
Gearbox selection bit 2
Gearbox switchover
Select SLP (SE) position range
Close brake from control
Select test stop
SGE valid
De-select external STOP A
De-select external STOP C
De-select external STOP D
De-select external STOP E
SLS (SG) override bit 0
SLS (SG) override bit 1
SLS (SG) override bit 2
SLS (SG) override bit 3
Signal name
De-select STO
De-select SS1
De-select SS2
De-select SOS
De-select SLS
Deselect SLP
Acknowledgment
Select SLS bit 0
Select SLS bit 1
Deselect SDI positive
Deselect SDI negative
Select SLP position range
Select gearbox bit 0
Select gearbox bit 1
Select gearbox bit 2
Gearbox switchover
Deselect SS2E
Set
Set
Set
Set
SLP2 (SE2)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Set
Set
Set
Set
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Signal edge active
Set
Set
Yes
Yes
SLP2
Set
Set
Set
Set
Yes
List Manual (LH2), 07/2016, A5E03263479A
Not set
Not set
Not set
Not set
SLP1 (SE1)
No
No
No
No
No
No
No
Not set
Not set
Not set
Not set
Access level: 3
Func. diagram: 2840, 2905
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
No
No
Not set
Not set
No
No
SLP1
Not set
Not set
Not set
Not set
No
SINAMICS G130/G150
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
FP
-
-
-
-
-
2822
-
-
-
2824
2824
2822
-
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents