p0874
BI: Smart/ Basic Line Module operation / SLM/BLM operation
B_INF
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: Commands
Not for motor type: -
Min
-
Description:
Setting to interconnect the ready signal for mixed operation of Smart Line Module (SLM) and Basic Line Module
(BLM).
In order that signal BO: r0873 is available at one of the infeeds, then BI: p0874 of the one infeed must be
interconnected to BO: r0863.0 of the other infeed.
Dependency:
Refer to: r0863, r0873
Note:
Mixed operation is not possible with the Active Line Module (ALM)!
p0894
Parking pre-setting / Parking pre-set
VECTOR_G, ENC
Can be changed: U, T
Data type: Unsigned32
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Pre-setting for the "Parking axis" and "Parking encoder" function.
Bit field:
Bit
00
Dependency:
Refer to: p0480, p0897
Note:
For bit 00:
If there is at least one BICO interconnection for "Parking axis" or "Parking encoder", this default setting is taken into
consideration during power up.
p0895[0...n]
BI: Activate/deactivate power unit components / PU_comp act/deact
VECTOR_G, B_INF
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Sets the signal source to activate/deactivate a power unit component.
Dependency:
BI: p0895 = 0 signal
Deactivate power unit components.
BI: p0895 = 1 signal
Activate power unit components
Refer to: p0125, r0126
Refer to: A05054
Caution:
It is not permissible to deactivate drive objects with safety functions enabled.
Notice:
For Active Line Modules in the "Chassis" format, the Voltage Sensing Module (VSM, p0145) belonging to the power
unit is automatically activated/deactivated.
Note:
The power unit is only deactivated when the pulses are suppressed.
For units connected in parallel, when one of the power units is deactivated, then the enable in p7001 is withdrawn.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Signal name
Default with interconnection
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Park
Calculated: -
Dyn. index: PDS, p0120
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 8732, 8832
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 bin
0 signal
Do not park
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
FP
-
285

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents