2 Parameters
2.2 List of parameters
p0445[0...n]
Encoder commissioning serial number part 5 / Enc comm ser_no 5
VECTOR_G, ENC
Can be changed: C2(4)
Data type: Unsigned32
P-Group: Encoder
Not for motor type: -
Min
0000 hex
Description:
Serial number part 5 of the encoder for the commissioning.
Dependency:
Refer to: p0440, p0441, p0442, p0443, p0444, r0460, r0461, r0462, r0463, r0464
Note:
A value of zero is displayed if an encoder is not present.
p0446[0...n]
Encoder SSI number of bits before the absolute value / Enc SSI bit before
VECTOR_G, ENC
Can be changed: C2(4)
Data type: Unsigned16
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the number of bits before the absolute value in the SSI protocol.
Notice:
This parameter is automatically preassigned for encoders from the encoder list and for identify encoder (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
Note:
For example, error bit, alarm bit or parity bit can be positioned at these bits.
p0447[0...n]
Encoder SSI number of bits absolute value / Enc SSI bit val
VECTOR_G, ENC
Can be changed: C2(4)
Data type: Unsigned16
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the number of bits for the absolute value in the SSI protocol.
Notice:
This parameter is automatically preassigned for encoders from the encoder list and for identify encoder (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
p0448[0...n]
Encoder SSI number of bits after the absolute value / Enc SSI bit after
VECTOR_G, ENC
Can be changed: C2(4)
Data type: Unsigned16
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the number of bits after the absolute value in the SSI protocol.
Notice:
This parameter is automatically preassigned for encoders from the encoder list and for identify encoder (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
Note:
For example, error bit, alarm bit or parity bit can be positioned at these bits.
182
Calculated: CALC_MOD_ALL
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
FFFF FFFF hex
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
65535
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
65535
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
65535
List Manual (LH2), 07/2016, A5E03263479A
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 hex
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
25
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
SINAMICS G130/G150