Siemens G130 List Manual page 700

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
Note:
SMI: SINAMICS Sensor Module Integrated
p4692 = 10: Automatic on successful completion of backup procedure.
p4692 = 13, 16, 20, 29: Error values if the procedure could not be executed successfully.
The procedure must be repeated if the data save operation was interrupted (e.g. if the power supply voltage failed).
Help for error value = 13:
- Use a memory card with more memory space.
Help for error value = 16:
- check the DRIVE-CLiQ wiring.
Help for error value = 20:
- Use an SMI that is not blank.
Help for error value = 29:
- check and correct the target and actual topologies for the SMIs.
- Repeat the save procedure.
p4693[0...1]
SMI spare part data backup directory / SMI dat_bkup dir
CU_G130_PN,
Can be changed: T
CU_G150_PN,
Data type: Unsigned16
CU_G130_DP,
P-Group: Displays, signals
CU_G150_DP
Not for motor type: -
Min
0
Description:
Sets the directory for downloading and saving data.
Example:
The SMI has the component number 5 and the SMI data (motor/encoder data) is to be stored in subdirectory C205.
--> p4690 = 5, p4693[0] = 205, p4691 = 1
Index:
[0] = Subdirectory selection
[1] = Reserved
Dependency:
Refer to: p4691, r4694
Notice:
If p4693[0] is not equal to 0 and p4693[0] is not equal to p4690, the following applies:
- Only a number >= 200 may be selected for the subdirectory when saving.
- in the case of downloads, a selection for the subdirectory may only be made for an SMI/DQI with a component
number >= 200 (preliminary component number) (p4690 >= 200).
Note:
DQI: DRIVE-CLiQ Sensor Integrated
SMI: SINAMICS Sensor Module Integrated
For index 0:
This index is used to select the subdirectory for saving and downloading data. The motor article number (MLFB) of
the corresponding data backup is displayed in r4694.
For p4693[0] = 0, the following applies:
The directory is determined by the setting of p4690.
r4694[0...19]
SMI spare part data backup motor article number / SMI dat_bkup MLFB
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: Unsigned8
CU_G130_DP,
P-Group: Displays, signals
CU_G150_DP
Not for motor type: -
Min
-
Description:
Displays the motor article number (MLFB) of the data backup selected with p4693.
Dependency:
Refer to: p4691, p4692
Caution:
If the selected subdirectory contains a number of data sets, "More Datasets" is displayed in r4694[0...19].
If there is no SMI data (motor/encoder data) in the selected subdirectory or if the selected subdirectory does not exist,
the following applies:
- the number of the next subdirectory located is displayed.
- this subdirectory is not checked for valid SMI data.
- if another subdirectory cannot be located, nothing is displayed in r4694[0...19].
700
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
399
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents