r1614
EMF maximum / EMF max
VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: ASM, PMSM, REL
Min
- [Vrms]
Description:
Displays the actual maximum possible electromotive force (EMF) of the separately excited synchronous motor.
Dependency:
The value is the basis for the flux setpoint.
The maximum possible EMF depends on the following factors:
- Actual DC link voltage (r0070).
- Maximum modulation depth (p1803).
- Field-generating and torque-generating current setpoint.
p1616[0...n]
Current setpoint smoothing time / I_set T_smooth
VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
4 [ms]
Description:
Sets the smoothing time for the current/torque setpoint in the open-loop-controlled operating range in the case of
sensorless vector control.
Note:
This parameter is only effective in the range where current is injected for sensorless vector control.
For permanent magnet synchronous motors, the parameter is effective over the complete speed range.
For induction motors, the current setpoint is calculated from p1610 and p1611 and for separately excited
synchronous motors the torque setpoint is calculated from p1610 and p1611.
r1617
CO: Torque setpoint (controlled) / M_set ctrl
VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PMSM, REL
Min
- [Nm]
Description:
Torque setpoint for sensorless control of the separately excited synchronous motor in the open-loop-controlled
operating range (under p1755 * p1756).
r1618
Current model controller pre-control / I_mod_ctrl prectrl
VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PMSM, REL
Min
- [Arms]
Description:
Displays the pre-control value of the current model controller.
It involves a magnetizing current in the d-direction.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: -
Unit group: 5_1
Scaling: p2001
Max
- [Vrms]
Calculated: CALC_MOD_REG
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
10000 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [Nm]
Calculated: -
Dyn. index: -
Unit group: 6_2
Scaling: p2002
Max
- [Arms]
2 Parameters
2.2 List of parameters
Access level: 4
Func. diagram: 6725
Unit selection: p0505
Expert list: 1
Factory setting
- [Vrms]
Access level: 3
Func. diagram: 6721, 6722,
6726
Unit selection: -
Expert list: 1
Factory setting
40 [ms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [Nm]
Access level: 4
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [Arms]
427