p0698[0...n]
Brushless excitation excitation resistance / BLE exc_resist
VECTOR_G (n/M)
Can be changed: C2(3), U, T
Data type: FloatingPoint32
P-Group: Motor
Not for motor type: ASM, PMSM, REL,
RESM
Min
-10.00000 [ohm]
Description:
Sets the ohmic excitation resistance of the main exciter machine for brushless excitation.
When the rotor resistance is known, this value can be added to the excitation resistance.
Notice:
For a value = 0, brushless excitation is not activated.
Note:
BLE: brushless excitation
p0700[0...n]
Macro Binector Input (BI) / Macro BI
VECTOR_G, B_INF
Can be changed: C2(1), T
Data type: Unsigned32
P-Group: Commands
Not for motor type: -
Min
0
Description:
Runs the corresponding macro files.
The binector inputs of the corresponding command data set are appropriately interconnected.
The selected macro file must be available on the memory card/device memory.
Example:
p0700 = 6 --> macro file PM000006.ACX is run.
Dependency:
Refer to: p0015, p1000, p1500, r8571
Notice:
No errors were issued during quick commissioning (p3900 = 1) when writing to parameters of the QUICK_IBN group!
When executing a specific macro, the corresponding programmed settings are made and become active.
Note:
The macros in the specified directory are displayed in r8571. r8571 is not in the expert list of the commissioning
software.
Macros available as standard are described in the technical documentation of the particular product.
BI: Binector Input
CDS: Command Data Set
p0700
Macro Binector Input (BI) for TMs / Macro BI TM
TM31, TB30
Can be changed: C2(1), T
Data type: Unsigned32
P-Group: Commands
Not for motor type: -
Min
0
Description:
Runs the corresponding macro files.
The selected macro file must be available on the memory card/device memory.
Example:
p0700 = 6 --> macro file PM000006.ACX is run.
Dependency:
Refer to: r8571
Notice:
No errors were issued during quick commissioning (p3900 = 1) when writing to parameters of the QUICK_IBN group!
When executing a specific macro, the corresponding programmed settings are made and become active.
Note:
The macros in the specified directory are displayed in r8571. r8571 is not in the expert list of the commissioning
software.
Macros available as standard are described in the technical documentation of the particular product.
BI: Binector Input
CDS: Command Data Set
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: MDS, p0130
Unit group: -
Scaling: -
Max
10.00000 [ohm]
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
999999
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
999999
2 Parameters
2.2 List of parameters
Access level: 4
Func. diagram: 6727
Unit selection: -
Expert list: 1
Factory setting
0.00000 [ohm]
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
253

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents