Siemens G130 List Manual page 1060

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p10201
SI Motion SBT enable / SBT enable
VECTOR_G
Can be changed: C2(95)
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Sets the enable for the safe brake test.
Bit field:
Bit
00
Note:
SBT: Safe Brake Test
p10202[0...1]
SI Motion SBT brake selection / SBT brake select
VECTOR_G
Can be changed: C2(95)
Data type: Integer16
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Selects the brakes to be tested.
Value:
0:
1:
2:
Index:
[0] = Brake 1
[1] = Brake 2
Dependency:
Refer to: p10203, p10230, p10235
Refer to: A01785
Note:
It is not possible to test two motor holding brakes. An appropriate message is output for an incorrect
parameterization.
The brake to be tested is selected using p10230[2] or p10235.2.
p10203
SI Motion SBT control selection / SBT control select
VECTOR_G
Can be changed: C2(95)
Data type: Integer16
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Selects the control for the safe brake test.
Value:
0:
1:
2:
Dependency:
Refer to: p9705, p10230, p10235, p10250
Note:
SCC: Safety Control Channel
For a value = 2, the following applies:
Brake 1 with sequence 1 (p10210[0], p10211[0], p10212[0], p10218) is tested. Brake 1 must be configured as motor
holding brake (p10202[0] = 1).
1060
Signal name
Enable safe brake test
Inhibit
Test motor holding brake
Test external brake
SBT via SCC (p10235)
SBT via BICO (p10230)
SBT for test stop selection (p9705/p10250.8)
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 bin
0 signal
No
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 2837
Unit selection: -
Expert list: 1
Factory setting
0
SINAMICS G130/G150
FP
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents