Siemens G130 List Manual page 993

Hide thumbs Also See for G130:
Table of Contents

Advertisement

r9765
SI Motion forced check procedure remaining time (Control Unit) / SI Mtn dyn remain
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
- [h]
Description:
Displays the time remaining until the next dynamization and testing of the safety motion monitoring functions
integrated in the drives.
The signal source to initiate the forced checking procedure is parameterized in p9705.
Dependency:
Refer to: p9705
Refer to: C01798
r9768[0...7]
SI PROFIsafe receive control words (Control Unit) / SI Ps PZD recv CU
VECTOR_G
Can be changed: -
Data type: Unsigned16
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Displays the received PROFIsafe telegram on the Control Unit.
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
Dependency:
Refer to: r9769
Note:
The PROFIsafe trailer at the end of the telegram is also displayed (2 words).
r9769[0...7]
SI PROFIsafe send status words (Control Unit) / SI Ps PZD send CU
VECTOR_G
Can be changed: -
Data type: Unsigned16
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Displays the PROFIsafe telegram to be sent on the Control Unit.
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
Dependency:
Refer to: r9768
Note:
The PROFIsafe trailer at the end of the telegram is also displayed (2 words).
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [h]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [h]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
993

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents