Siemens G130 List Manual page 1067

Hide thumbs Also See for G130:
Table of Contents

Advertisement

p10250
CI: SI Safety Control Channel control word S_STW1B / SCC S_STW1B
VECTOR_G
Can be changed: T
Data type: Unsigned32 / Integer16
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for control word S_STW1B of the Safety Control Channel.
Dependency:
Refer to: p10203, r10251
Note:
SCC: Safety Control Channel
r10251.8...12
CO/BO: SI Safety Control Channel control word S_STW1B diagnostics /
SCC S_STW1B diag
VECTOR_G
Can be changed: -
Data type: Unsigned32
P-Group: -
Not for motor type: -
Min
-
Description:
Display and BICO output for the diagnostics of control word S_STW1B of the safety control channel.
Bit field:
Bit
08
09
10
12
Dependency:
Refer to: p10250
Note:
SCC: Safety Control Channel
p60022
PROFIsafe telegram selection / Ps telegram_sel
VECTOR_G
Can be changed: T
Data type: Unsigned16
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Sets the telegram number for PROFIsafe.
Value:
0:
30:
31:
901:
902:
Dependency:
Refer to: p9611, p9811
Note:
For p9601.3 = p9801.3 = 1 (PROFIsafe enabled), the following variants exist when parameterizing PROFIsafe
telegram 30:
- p9611 = p9811 = 998 and p60022 = 0
- p9611 = p9811 = 998 and p60022 = 30
- p9611 = p9811 = 30 and p60022 = 30
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Signal name
Extended functions test stop selection
Extended Functions referencing trigger
Extended Functions referencing reset
Extended Functions premature SOS after
STOP D
No PROFIsafe telegram selected
PROFIsafe standard telegram 30, PZD-1/1
PROFIsafe standard telegram 31, PZD-2/2
PROFIsafe SIEMENS telegram 901, PZD-3/5
PROFIsafe SIEMENS telegram 902, PZD-3/6
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Selected
Selected
Selected
Selected
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
902
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Not selected
Not selected
Not selected
Not selected
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
FP
2837
-
-
-
1067

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150