Siemens G130 List Manual page 890

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p8986
Web server configuration / Web serv config
CU_G130_PN,
Can be changed: T
CU_G150_PN,
Data type: Unsigned16
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
-
Description:
Setting to activate and configure the "Web server" function in the drive.
It is possible to access the web server via the integrated Ethernet and PROFINET interfaces of the drive. The
addressing is realized via the set IP address.
Bit field:
Bit
00
01
02
03
p8987[0...1]
Web server port assignment / WebServ PortAssign
CU_G130_PN,
Can be changed: T
CU_G150_PN,
Data type: Unsigned16
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
1
Description:
This parameter allows the port setting for the web server to be changed.
Index:
[0] = Port for standard transfer (http)
[1] = Port for secure transfer (https)
p9206[0...2]
Topology direct access / Topo access
CU_G130_PN,
Can be changed: T
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
P-Group: Topology
CU_G150_DP
Not for motor type: -
Min
0
Description:
Data setting to read topology properties.
The result is displayed depending on the property in r9207 or r9208.
For index 0:
0: actual topology, 1: target topology
For index 1:
Sets the component number of the component involved.
For index 2:
7: Name (r9208)
8: Component type (r9207)
9: Number of DRIVE-CLiQ connections (r9207)
11: Manufacturer (upper byte) and version (lower byte) (r9207)
12: Serial number (r9208)
13: Index (r9207)
15: Comparison level (r9207)
23: Article number (r9207)
24: Hardware serial number (r9208)
25: Envelope article number (r9207)
28: Firmware version (r9207)
890
Signal name
Activating
Only permit access via https
Enable "SINAMICS" user
Enable "Administrator" user
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
32767
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
4294967295
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0101 bin
0 signal
No
No
No
No
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
[0] 80
[1] 443
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
SINAMICS G130/G150
FP
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents