r9711[0...1]
SI Motion diagnostics result list 2 / SI Mtn res_list 2
VECTOR_G
Can be changed: -
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Displays result list 2 that, for the crosswise data comparison between the monitoring channels, led to the fault.
Index:
[0] = Result list second channel
[1] = Result list drive
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
Dependency:
Refer to: C01711
Note:
SCA: Safe Cam
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring)
r9712
CO: SI Motion diagnostics position actual value motor side / SI Mtn s_act mot
VECTOR_G
Can be changed: -
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Displays the actual motor-side position actual value for the motion monitoring functions on the Control Unit.
Note:
The display is updated in the safety monitoring clock cycle.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Signal name
Actual value > upper limit SCA1+
Actual value > lower limit SCA1+
Actual value > upper limit SCA1-
Actual value > lower limit SCA1-
Actual value > upper limit SCA2+
Actual value > lower limit SCA2+
Actual value > upper limit SCA2-
Actual value > lower limit SCA2-
Actual value > upper limit SCA3+
Actual value > lower limit SCA3+
Actual value > upper limit SCA3-
Actual value > lower limit SCA3-
Actual value > upper limit SCA4+
Actual value > lower limit SCA4+
Actual value > upper limit SCA4-
Actual value > lower limit SCA4-
Actual value > upper limit SSM+
Actual value > lower limit SSM+
Actual value > upper limit SSM-
Actual value > lower limit SSM-
Actual value > upper limit modulo
Actual value > lower limit modulo
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-