2 Parameters
2.2 List of parameters
p4078[0...1]
TB30 analog outputs characteristic value y1 / TB30 AO char y1
TB30
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Terminals
Not for motor type: -
Min
-11.000 [V]
Description:
Sets the scaling characteristic for the analog outputs of Terminal Board 30 (TB30).
The scaling characteristic for the analog outputs is defined using 2 points.
This parameter specifies the y coordinate (output voltage in V) of the 1st value pair of the characteristic.
Index:
[0] = AO 0 (X482.5/X482.6)
[1] = AO 1 (X482.7/X482.8)
Note:
The parameters for the characteristic do not have a limiting effect.
p4079[0...1]
TM31 analog outputs characteristic value x2 / TM31 AO char x2
TM31
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Terminals
Not for motor type: -
Min
-1000.00 [%]
Description:
Sets the scaling characteristic for the analog outputs of Terminal Module 31 (TM31).
The scaling characteristic for the analog outputs is defined using 2 points.
This parameter specifies the x coordinate (percentage) of the 2nd value pair of the characteristic.
Index:
[0] = AO 0 (X522.1, X522.2, X522.3)
[1] = AO 1 (X522.4, X522.5, X522.6)
Dependency:
Refer to: r4076, p4076
Notice:
This parameter is automatically overwritten when changing p4076 (type of analog outputs).
Note:
The parameters for the characteristic do not have a limiting effect.
p4079[0...1]
TB30 analog outputs characteristic value x2 / TB30 AO char x2
TB30
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Terminals
Not for motor type: -
Min
-1000.00 [%]
Description:
Sets the scaling characteristic for the analog outputs of Terminal Board 30 (TB30).
The scaling characteristic for the analog outputs is defined using 2 points.
This parameter specifies the x coordinate (percentage) of the 2nd value pair of the characteristic.
Index:
[0] = AO 0 (X482.5/X482.6)
[1] = AO 1 (X482.7/X482.8)
Note:
The parameters for the characteristic do not have a limiting effect.
660
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
11.000 [V]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1000.00 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1000.00 [%]
List Manual (LH2), 07/2016, A5E03263479A
Access level: 2
Func. diagram: 9106
Unit selection: -
Expert list: 1
Factory setting
0.000 [V]
Access level: 2
Func. diagram: 9572
Unit selection: -
Expert list: 1
Factory setting
100.00 [%]
Access level: 2
Func. diagram: 9106
Unit selection: -
Expert list: 1
Factory setting
100.00 [%]