Siemens G130 List Manual page 289

Hide thumbs Also See for G130:
Table of Contents

Advertisement

r0899.0...12
CO/BO: Status word sequence control infeed / ZSW seq_ctrl INF
B_INF
Can be changed: -
Data type: Unsigned16
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Display and BICO output for the status word of the sequence control of the infeed unit.
Bit field:
Bit
00
01
02
04
06
08
09
11
12
Note:
For bits 00, 01, 02, 04, 06, 09:
For PROFIdrive, these signals are used for status word 1.
r0899.7...9
CO/BO: Status word sequence control encoder DO / ZSW seq_ctrl encDO
ENC
Can be changed: -
Data type: Unsigned16
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the status word for sequence control on the encoder drive object.
Bit field:
Bit
07
09
Note:
For PROFIdrive, this signal is used for status word ZSW2_ENC.
p0918
PROFIBUS address / PB address
CU_G130_DP,
Can be changed: T
CU_G150_DP
Data type: Unsigned16
P-Group: Communications
Not for motor type: -
Min
1
Description:
Displays or sets the PROFIBUS address for PROFIBUS interface on the Control Unit.
The address can be set as follows:
1) Using the address switch on the Control Unit.
--> p0918 can then only be read and displays the selected address.
--> A change only becomes effective after a POWER ON.
2) Using p0918
--> Only if the address 00 hex, 7F hex, 80 hex, or FF hex has been set using the address switch.
--> The address is saved in a non-volatile fashion using the function "copy from RAM to ROM".
--> A change only becomes effective after a POWER ON.
Note:
Permissible PROFIBUS addresses: 1 ... 126 (01 hex ... 7E hex)
Address 126 is used for commissioning.
Every PROFIBUS address change only becomes effective after a POWER ON.
The parameter is not influenced by setting the factory setting.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Signal name
Ready for switching on
Ready
Operation enabled
No OFF2 active
Switching-on inhibited
Switching-on operation active
Control request
Precharging complete
Line contactor closed
Signal name
Drive ready
Control request
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
OFF2 inactive
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
126
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 8726
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
OFF2 active
No
No
No
No
No
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
Access level: 2
Func. diagram: 2401, 2410
Unit selection: -
Expert list: 1
Factory setting
126
FP
-
-
-
-
-
-
-
-
-
FP
-
-
289