p1563[0...n]
CO: Mom. of inertia estimator load torque direction of rotation pos. / J_est M pos
VECTOR_G
Can be changed: U, T
(J_estimator)
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
-340.28235E36 [Nm]
Description:
Display and connector output for the monitored load torque in the positive direction of rotation.
The moment of inertia estimator estimates the load torque drawn while the speed is constant.
Dependency:
Refer to: p1400, p1560, p1561
p1564[0...n]
CO: Mom. of inertia estimator load torque direction of rotation neg. / J_est M neg
VECTOR_G
Can be changed: U, T
(J_estimator)
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
-340.28235E36 [Nm]
Description:
Display and connector output for the monitored load torque in the negative direction of rotation.
The moment of inertia estimator estimates the load torque drawn while the speed is constant.
Dependency:
Refer to: p1400, p1560, p1561
r1566[0...n]
Flux reduction torque factor transition value / Flux red M trans
VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PMSM, SESM,
REL
Min
- [%]
Description:
The following applies for a synchronous reluctance motor:
Displays the transition value for the start of the evaluation of the optimum flux characteristic.
The value is referred to the rated motor torque.
Note:
The transition value corresponds with the lower limit of the flux setpoint (p1581).
For a lower absolute torque setpoint, the flux setpoint remains at the lower limit (p1581).
p1567[0...n]
Magnetization rate time scaling / Mag Tv scale
VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PMSM, SESM,
REL
Min
0 [%]
Description:
The following applies for a synchronous reluctance motor:
Sets the scaling of the rate time Tv for dynamic flux increase when the torque is quickly established.
The value is referred to the inverse value of the rated motor frequency.
Tv = p1567 / 100 % / p0310
Dependency:
Refer to: p1401
Note:
The "Dynamic load-dependent flux boost" function can be deactivated using p1401.9 = 0.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: p2003
Max
340.28235E36 [Nm]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: p2003
Max
340.28235E36 [Nm]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: CALC_MOD_CON
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
1000 [%]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.00 [Nm]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.00 [Nm]
Access level: 3
Func. diagram: 6790
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 4
Func. diagram: 6790
Unit selection: -
Expert list: 1
Factory setting
100 [%]