Siemens G130 List Manual page 154

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
Notice:
For permanent magnet synchronous motors (PMSM), the following applies:
If the parameters are not set as specified, i.e. not in ascending order and to more than 20 %, the unsaturated
quadrature inductance (p0356) is always used for quadrature axis flux calculation purposes.
Note:
When quick commissioning is exited with p3900 > 0, then the parameter is reset if a catalog motor has not been
selected (p0300).
r0370[0...n]
Motor stator resistance cold / Mot R_stator cold
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Motor
Not for motor type: -
Min
- [ohm]
Description:
Displays the motor stator resistance at an ambient temperature (p0625).
The value does not include the cable resistance.
Dependency:
Refer to: p0625
r0372[0...n]
Total power unit cable resistance / PU cable R tot
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Motor
Not for motor type: -
Min
- [ohm]
Description:
Displays the total cable resistance between Motor Module and motor, as well as the internal converter resistance.
Dependency:
Refer to: r0238, p0352
r0373[0...n]
Motor rated stator resistance / Mot R_stator rated
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Motor
Not for motor type: PMSM, SESM, REL
Min
- [ohm]
Description:
Displays the rated motor stator resistance at rated temperature (total of p0625 and p0627).
Dependency:
Refer to: p0627
Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
r0374[0...n]
Motor rotor resistance cold / damping resistance d axis / Mot R_r cold/R_D d
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Motor
Not for motor type: PMSM, REL, RESM
Min
- [ohm]
Description:
Displays the rotor/secondary section resistance of the motor for the ambient temperature p0625.
For separately excited synchronous motors:
Displays the damping resistance in the rotor direction (d-axis).
Dependency:
Refer to: p0625
Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
154
Calculated: -
Dyn. index: MDS, p0130
Unit group: 16_1
Scaling: -
Max
- [ohm]
Calculated: -
Dyn. index: MDS, p0130
Unit group: 16_1
Scaling: -
Max
- [ohm]
Calculated: -
Dyn. index: MDS, p0130
Unit group: 16_1
Scaling: -
Max
- [ohm]
Calculated: -
Dyn. index: MDS, p0130
Unit group: 16_1
Scaling: -
Max
- [ohm]
List Manual (LH2), 07/2016, A5E03263479A
Access level: 4
Func. diagram: -
Unit selection: p0349
Expert list: 1
Factory setting
- [ohm]
Access level: 4
Func. diagram: -
Unit selection: p0349
Expert list: 1
Factory setting
- [ohm]
Access level: 4
Func. diagram: -
Unit selection: p0349
Expert list: 1
Factory setting
- [ohm]
Access level: 4
Func. diagram: -
Unit selection: p0349
Expert list: 1
Factory setting
- [ohm]
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150