Siemens G130 List Manual page 911

Hide thumbs Also See for G130:
Table of Contents

Advertisement

p9354
SI Motion transition time STOP E to SOS (Motor Module) / SI Mtn t E->SOS MM
VECTOR_G
Can be changed: C2(95)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [µs]
Description:
Sets the transition time from STOP E to "Safe Operating Stop" (SOS).
Dependency:
Refer to: p9554
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
SOS: Safe Operating Stop
p9355
SI Motion transition time STOP F to STOP B (Motor Module) / SI Mtn t F->B MM
VECTOR_G
Can be changed: C2(95)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [µs]
Description:
Sets the transition time from STOP F to STOP B.
Dependency:
Refer to: C01711
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
p9356
SI Motion STOP A delay time (Motor Module) / SI Mtn IL t_del MM
VECTOR_G
Can be changed: C2(95)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [µs]
Description:
Sets the delay time for STOP A after STOP B / SS1.
In the case of encoderless motion monitoring functions with safe brake ramp monitoring (p9306 = 1) and the OFF3
ramp enabled at the same time (p9507.3 = 0), the parameter has no effect.
Dependency:
Refer to: p9360, p9556
Refer to: C01701
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
SS1: Safe Stop 1
p9357
SI Motion STO test time (Motor Module) / SI Mtn IL t MM
VECTOR_G
Can be changed: C2(95)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [µs]
Description:
Sets the time after which STO must be active when initiating the test stop.
Dependency:
Refer to: p9557
Refer to: C01798
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
600000000.00 [µs]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
600000000.00 [µs]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
3600000000.00 [µs]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
10000000.00 [µs]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
100000.00 [µs]
Access level: 3
Func. diagram: 2819
Unit selection: -
Expert list: 1
Factory setting
0.00 [µs]
Access level: 3
Func. diagram: 2819
Unit selection: -
Expert list: 1
Factory setting
100000.00 [µs]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
100000.00 [µs]
911