Siemens G130 List Manual page 723

Hide thumbs Also See for G130:
Table of Contents

Advertisement

p4810
Function generator mode / FG operating mode
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: Integer16
CU_G130_DP,
P-Group: Trace and function generator
CU_G150_DP
Not for motor type: -
Min
0
Description:
Sets the operating mode of the function generator.
Value:
0:
1:
2:
3:
4:
5:
6:
99:
p4812
Function generator physical address / FG phys address
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
P-Group: Trace and function generator
CU_G150_DP
Not for motor type: -
Min
0
Description:
Sets the physical address where the function generator is to be connected.
Dependency:
Only effective when p4810 = 99.
p4813
Function generator physical address reference value / FG phys addr ref
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: FloatingPoint32
CU_G130_DP,
P-Group: Trace and function generator
CU_G150_DP
Not for motor type: -
Min
1.00
Description:
Sets the reference value for 100 % for referred inputs.
Dependency:
Only effective when p4810 = 99.
p4815[0...2]
Function generator drive number / FG drive number
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: Unsigned16
CU_G130_DP,
P-Group: Trace and function generator
CU_G150_DP
Not for motor type: -
Min
0
Description:
Selects the required drive where the function generator is to be connected.
Index:
[0] = First drive for connection
[1] = Second drive for connection
[2] = Third drive for connection
Dependency:
Only effective when p4810 = 1, 2, 3, 4 or 5.
Note:
For the function generator, only type SERVO, VECTOR or DC_CTRL type drives can be used.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Connection at connector output r4818
Connection at current setpoint after filter and r4818
Connection as disturbing torque and r4818
Connection at speed setpoint after filter and r4818
Connection at current setpoint before filter and r4818
Connection at speed setpoint before filter and r4818
Connection for free measurement function r4818 and r4834
Connection at physical address and r4818
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
99
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
4294967295
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1000000.00
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
65535
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
1.00
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0
723