Siemens G130 List Manual page 1004

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
It is not permissible to parameterize "motor holding brake without feedback signals" and also enable "safe brake
control" (p1278 = 1, p9602 = 1, p9802 = 1).
MM: Motor Module
SBC: Safe Brake Control
SI: Safety Integrated
p9810
SI PROFIsafe address (Motor Module) / SI PROFIsafe MM
VECTOR_G
Can be changed: C2(95)
Data type: Unsigned16
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Sets the PROFIsafe address of the Motor Module/Hydraulic module.
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
p9811
SI PROFIsafe telegram selection (Motor Module) / SI Ps telegram MM
VECTOR_G
Can be changed: C2(95)
Data type: Unsigned16
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Sets the PROFIsafe telegram number for the Motor Module/Hydraulic Module.
Value:
0:
30:
31:
900:
901:
902:
998:
Dependency:
Refer to: p9611, p60022
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
For p9601.3 = p9801.3 = 1 (PROFIsafe enabled), the following variants exist when parameterizing PROFIsafe
telegram 30:
- p9611 = p9811 = 998 and p60022 = 0
- p9611 = p9811 = 998 and p60022 = 30
- p9611 = p9811 = 30 and p60022 = 30
p9812
SI PROFIsafe failure response (Motor Module) / SI Ps fail MM
VECTOR_G
Can be changed: C2(95)
Data type: Integer16
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Sets the stop response when PROFIsafe communication fails.
Value:
0:
1:
Dependency:
Refer to: p9612
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
1004
No PROFIsafe telegram selected
PROFIsafe standard telegram 30, PZD-1/1
PROFIsafe standard telegram 31, PZD-2/2
PROFIsafe SIEMENS telegram 900, PZD-2/2
PROFIsafe SIEMENS telegram 901, PZD-3/5
PROFIsafe SIEMENS telegram 902, PZD-3/6
Compatibility mode (as for firmware version < 4.5)
STOP A
STOP B
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
65534
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
998
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
998
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents