Siemens G130 List Manual page 883

Hide thumbs Also See for G130:
Table of Contents

Advertisement

r8935[0...5]
PN MAC address / PN MAC addr
CU_G130_PN,
Can be changed: -
CU_G150_PN
Data type: Unsigned8
P-Group: -
Not for motor type: -
Min
0000 hex
Description:
Displays the MAC address for the onboard PROFINET interface on the Control Unit.
r8936[0...1]
PN cyclic connection state / PN cyc conn state
CU_G130_PN,
Can be changed: -
CU_G150_PN
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Displays the state of the cyclic PROFINET connections.
Value:
0:
1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
Index:
[0] = Controller 1
[1] = Controller 2
Dependency:
Refer to: p8929, r8961, r8962
Note:
For two connections (Shared Device or system redundancy) the display in the index depends on the sequence in
which the connections are established.
The IP addresses of controllers 1 and 2 are displayed in r8961 and r8962.
The following states are displayed for system redundancy:
Primary controller: r8936[x] = 13
Backup controller: r8936[x] = 11
If value = 10:
If the connection remains in this state, then when using PROFINET IRT the following can apply:
- topology error (incorrect port assignment).
- synchronization missing.
r8937[0...5]
PN diagnostics / PN diag
CU_G130_PN,
Can be changed: -
CU_G150_PN
Data type: Unsigned32
P-Group: -
Not for motor type: -
Min
-
Description:
Display to diagnose the cyclic PROFINET connections.
Index:
[0] = Number of cyclic connections
[1] = Number of send subslots of all connections
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Interrupted
Not connected
Connection starts to be established
Module information expected
Module information received
Module address expected
Module address received
Parameterization data expected
Parameterization data received
Evaluate parameterization data
Connection being established completion expected
Configured controller RUN expected
Configured controller STOP
Configured controller RUN
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
00FF hex
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
13
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-