SI Motion function specification (Motor Module) / SI Mtn fct_spc MM
VECTOR_G
Can be changed: C2(95)
Data type: Integer16
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Sets the function specification for the safe motion monitoring.
Value:
0:
1:
2:
3:
Dependency:
Refer to: C30711
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
p9307
SI Motion function configuration MM / SI mtn config MM
VECTOR_G
Can be changed: C2(95)
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Sets the function configuration for the safe motion monitoring functions.
Bit field:
Bit
00
01
02
03
05
06
Dependency:
Refer to: C01711
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
For bit 00:
When the function is activated, a safety-relevant acknowledgment (internal event acknowledge) can be performed by
selecting/deselecting STO.
For bit 01:
When the function is activated, the active setpoint velocity limit (CO: r9733) is set to zero when STOP F is active.
For bit 02:
This bit defines the type of motor, which the sensorless actual value sensing evaluates.
For bit = 0, the actual velocity is calculated for an induction motor.
For bit = 1, the actual velocity is calculated for a synchronous motor. This value depends on the setting in p0300.
Bit = 0 should be set if no motor is defined (p0300 = 0).
For bit 03:
When the bit is activated – when selecting function SS1 or activating a STOP B – an SS1E or a STOP B with Stop,
which should be externally initiated, is triggered instead of SS1 with a drive-based braking response. As a
consequence, brake monitoring (SBR, SAM) is deactivated.
SS1E: Safe Stop 1 external (Safe Stop 1 with external stop)
For bit 05:
This bit defines the type of modulation, which the sensorless actual value sensing evaluates.
For bit = 0, the actual velocity is calculated for space vector modulation.
For bit = 1, the actual velocity is calculated for edge modulation. This value depends on the setting in p1802.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Safety with encoder and accel_monitoring(SAM) / delay time
Safety without encoder and braking ramp(SBR)
Safety with encoder and braking ramp (SBR)
Safety without encoder with accel_monitoring(SAM) / delay time
Signal name
Extended message acknowledgment
Setpoint velocity limit for STOP F
Actual value sensing sensorless motor type Synchronous motor
SS1 with OFF3 (brake response)
Actual value sensing sensorless edge
modulation
Configuration test stop motion monitoring
functions
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
3
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
No
SS1E external stop
Yes
Test automatic
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 0000 bin
0 signal
No
Yes
Induction motor
SS1 with OFF3
No
Test manual
FP
-
-
-
-
-
-
895