2 Parameters
2.2 List of parameters
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
Dependency:
Refer to: r0193
Notice:
This information represents the characteristics/features of the power unit firmware. It does not provide
information/data about the characteristics/features of the hardware (e.g. bit 06 = 1 means that although the firmware
supports "liquid cooling", a power unit with liquid cooling does not have to be used).
Note:
For bit 09:
The Motor Module supports the internal armature short-circuit. The function is internally required for voltage
protection (p1231 = 3).
For bit 10:
The Motor Module supports the autonomous internal voltage protection.
If the "internal voltage protection" function is activated (p1231 = 3) the Motor Module decides autonomously - using
the DC link voltage - as to whether the short-circuit is activated.
For bit 23:
The component supports the detection of current actual values (and the detection of valve close durations) with
double clocking and phase shift.
106
Liquid cooling
SERVO pulse frequency changeover DDS-
dependent
Simulation mode possible
Internal armature short-circuit possible
Autonomous internal armature short-circuit
possible
Infeed temperature inputs X21.1/2
Integral scaled to half the gating unit clock
cycle freq.
Filtering thermal power unit current limit
possible
DC link compensation possible in power unit Yes
PT100 temperature evaluation possible
Gating unit with pulse frequency
wobbulation possible
Compound braking possible
Extended voltage range possible
Gating unit available with current limitation
control
Component status possible
Temperature evaluation via Motor Module /
CU terminals possible
Reduced device supply voltage possible
Current measurement oversampling
available
Parking keeping the relevant data is
available
Internal fan operating hours counter
available
Software gating unit supported in the
Control Unit
Current controller dynamics higher
Reserved
Voltage measurement
Gating unit with all-phase current limiting
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
List Manual (LH2), 07/2016, A5E03263479A
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
SINAMICS G130/G150
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-