Siemens G130 List Manual page 225

Hide thumbs Also See for G130:
Table of Contents

Advertisement

p0524[0...19]
Scaling specific parameters referred to p0514[9] / Scal spec p514[9]
VECTOR_G, B_INF
Can be changed: T
Data type: Unsigned32
P-Group: Communications
Not for motor type: -
Min
0
Description:
Sets the parameters with reference value in p0514[9] for the specific scaling.
p0524[0]: parameter number
p0524[1]: parameter number
p0524[2]: parameter number
...
p0524[19]: parameter number
Dependency:
Refer to: p0514
p0528
Controller gain system of units / Ctrl_gain unit_sys
VECTOR_G
Can be changed: C2(5)
Data type: Integer16
P-Group: Applications
Not for motor type: -
Min
0
Description:
Sets the system of units for the controller gains.
Value:
0:
1:
Note:
For VECTOR (r0107) the following applies:
The parameter is pre-assigned a value of 1 and cannot be changed.
p0528
Controller gain system of units / Ctrl_gain unit_sys
ENC
Can be changed: C2(5)
Data type: Integer16
P-Group: Applications
Not for motor type: -
Min
0
Description:
Sets the system of units for the controller gains.
Value:
0:
1:
Note:
The parameter is pre-assigned a value of 0 and cannot be changed.
p0530[0...n]
Bearing version selection / Bearing vers sel
VECTOR_G
Can be changed: C2(1, 3)
Data type: Unsigned16
P-Group: Motor
Not for motor type: SESM
Min
0
Description:
Sets the bearing version.
Corresponding to the bearing version entered, its code number (p0531) is automatically set.
0 = No data
1 = Manual entry
101 = STANDARD
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Representation physical/% (p0505)
Representation no dimensions (referred)
Representation physical/% (p0505)
Representation no dimensions (referred)
Calculated: CALC_MOD_ALL
Dyn. index: -
Unit group: -
Scaling: -
Max
4294967295
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: MDS, p0130
Unit group: -
Scaling: -
Max
104
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
225

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents