Siemens G130 List Manual page 885

Hide thumbs Also See for G130:
Table of Contents

Advertisement

Note:
The interface configuration (p8940 and following) is activated with p8945.
The parameter is not influenced by setting the factory setting.
p8942[0...3]
CBE2x Default Gateway / CBE2x Def Gateway
CU_G130_PN (PN
Can be changed: U, T
CBE20),
Data type: Unsigned8
CU_G150_PN (PN
P-Group: -
CBE20),
Not for motor type: -
CU_G130_DP (PN
CBE20),
Min
CU_G150_DP (PN
0
CBE20)
Description:
Sets the standard gateway for the Communication Board Ethernet 20/25 (CBE20/CBE25).
Dependency:
Refer to: p8945, r8952
Note:
The setting p8942[0...3] = 0 or p8942 = p8941 (own IP address) means that a standard gateway has not been set.
The interface configuration (p8940 and following) is activated with p8945.
The parameter is not influenced by setting the factory setting.
p8943[0...3]
CBE2x Subnet Mask / CBE2x Subnet Mask
CU_G130_PN (PN
Can be changed: U, T
CBE20),
Data type: Unsigned8
CU_G150_PN (PN
P-Group: -
CBE20),
Not for motor type: -
CU_G130_DP (PN
CBE20),
Min
CU_G150_DP (PN
0
CBE20)
Description:
Sets the subnet mask for the Communication Board Ethernet 20/25 (CBE20/CBE25).
Dependency:
Refer to: p8945, r8953
Note:
The interface configuration (p8940 and following) is activated with p8945.
The parameter is not influenced by setting the factory setting.
p8944
CBE2x DHCP Mode / CBE2x DHCP Mode
CU_G130_PN (PN
Can be changed: U, T
CBE20),
Data type: Integer16
CU_G150_PN (PN
P-Group: -
CBE20),
Not for motor type: -
CU_G130_DP (PN
CBE20),
Min
CU_G150_DP (PN
0
CBE20)
Description:
Sets the DHCP mode for the Communication Board Ethernet 20/25 (CBE20/CBE25).
Value:
0:
2:
3:
Dependency:
Refer to: p8945, r8954
Notice:
When the DHCP mode is active (p8944 not equal to 0), then PROFINET communication via this interface is no longer
possible! However, the interface can be used by the STARTER/SCOUT commissioning tool.
Note:
The interface configuration (p8940 and following) is activated with p8945.
The parameter is not influenced by setting the factory setting.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
DHCP off
DHCP on, identification using MAC address
DHCP on, identification via name of station
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
255
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
255
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
3
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
885

Hide quick links:

Advertisement