r0193
Power unit firmware properties 2 / PU FW property 2
VECTOR_G, B_INF
Can be changed: -
Data type: Unsigned32
P-Group: Converter
Not for motor type: -
Min
-
Description:
Displays the properties supported by the power unit firmware.
Bit field:
Bit
01
06
08
09
Dependency:
Refer to: r0192
r0194[0...n]
VSM properties / VSM properties
VECTOR_G
Can be changed: -
Data type: Unsigned32
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the properties supported by the Voltage Sensing Module (VSM).
Bit field:
Bit
00
r0196[0...255]
Topology component status / Top comp stat
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
-
Description:
Displays the status of the components.
r0196[0]: group status of all components
r0196[1]: Status of component with component number 1
...
r0196[255]: Status of component with component number 255
Bit field:
Bit
00
01
02
03
04
06
07
08
09
10
11
12
13
14
15
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Signal name
Component trace
PT1000 temperature sensor evaluation
Reduced undervoltage threshold during
precharging
Switchover to 1-phase line voltage
Signal name
Reserved
Signal name
Component status bit 0
Component status bit 1
Component status bit 2
Component status bit 3
Component state
Topology problem active
Part of the target topology
Alarm present
Safety message present
Fault present
Alarm class bit 0
Alarm class bit 1
Maintenance required
Maintenance urgently required
Fault gone/can be acknowledged
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: p0150
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
High
High
High
High
Active
Yes
Yes
Yes
Yes
Yes
High
High
Yes
Yes
Yes
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Low
Low
Low
Low
Inactive/parking
No
No only act topo
No
No
No
Low
Low
No
No
No
FP
-
-
-
-
FP
-
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
107

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents