2 Parameters
2.2 List of parameters
p0006
BOP operating display mode / BOP op_ disp mode
VECTOR_G, B_INF
Can be changed: U, T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the mode of the operating display for the Basic Operator Panel (BOP) in the operating states "ready for
operation" and "operation".
Value:
0:
1:
2:
3:
4:
Dependency:
Refer to: p0005
Note:
Mode 0 ... 3 can only be selected if also r0020, r0021 are available on the drive object.
Mode 4 is available for all drive objects.
p0007
BOP background lighting / BOP lighting
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
0 [s]
Description:
Sets the delay time until the background lighting of the Basic Operator Panel (BOP) is switched off.
If no keys are actuated, then the background lighting automatically switches itself off after this time has expired.
Note:
p0007 = 0: Background lighting is always switched on (factory setting).
p0008
BOP drive object after booting / BOP DO after boot
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: Unsigned16
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
1
Description:
Sets the required drive object that is active at the Basic Operator Panel (BOP) after booting.
Note:
The value from p0008 initializes the display on the Basic Operator Panel (BOP) at the top left after booting.
The drive object Control Unit is selected using the value 1.
p0009
Device commissioning parameter filter / Dev comm par_filt
CU_G130_PN,
Can be changed: C1, T
CU_G150_PN,
Data type: Integer16
CU_G130_DP,
P-Group: All groups
CU_G150_DP
Not for motor type: -
Min
0
Description:
Sets the device and basic drive commissioning.
By appropriately setting this parameter, those parameters are filtered that can be written into in the various
commissioning steps.
Value:
0:
1:
2:
40
Operation --> r0021, otherwise r0020 <--> r0021
Operation --> r0021, otherwise r0020
Operation --> p0005, otherwise p0005 <--> r0020
Operation --> r0002, otherwise r0002 <--> r0020
p0005
Ready
Device configuration
Defining the drive type/function module
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
4
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2000 [s]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
65535
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
10000
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
4
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0 [s]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1