2 Parameters
2.2 List of parameters
Note:
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The speed actual value is available smoothed (r0021, r0022) and unsmoothed (r0063).
r0022
Speed actual value rpm smoothed / n_act rpm smooth
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [rpm]
Description:
Displays the smoothed actual value of the motor speed.
Frequency components from the slip compensation (for induction motors) are not included.
r0022 is identical to r0021, however, it always has units of rpm and contrary to r0021 cannot be changed over.
Dependency:
Refer to: r0021, r0063
Note:
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The speed actual value is available smoothed (r0021, r0022) and unsmoothed (r0063).
r0024
Output frequency smoothed / f_outp smooth
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [Hz]
Description:
Display of the smoothed output frequency.
Frequency components from the slip compensation (for induction motors) are included.
Dependency:
Refer to: r0066
Note:
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The output frequency is available smoothed (r0024) and unsmoothed (r0066).
r0025
CO: Output voltage smoothed / U_outp smooth
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [Vrms]
Description:
Displays the smoothed output voltage of the power unit.
Dependency:
Refer to: r0072
Note:
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The output voltage is available smoothed (r0025) and unsmoothed (r0072).
48
Calculated: -
Dyn. index: -
Unit group: -
Scaling: p2000
Max
- [rpm]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: p2000
Max
- [Hz]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: p2001
Max
- [Vrms]
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: 6799
Unit selection: -
Expert list: 1
Factory setting
- [rpm]
Access level: 3
Func. diagram: 6300, 6799
Unit selection: -
Expert list: 1
Factory setting
- [Hz]
Access level: 2
Func. diagram: 5730, 6300,
6799
Unit selection: -
Expert list: 1
Factory setting
- [Vrms]